Honeywell L Series Aquastats Excerpting from Honeywell's manual for this controller, The L Aquastat® Relays are immersion type hydronic controllers that combine high limit protection with switching relay control of burner and circulator motors. This Honeywell Lseries aquastat Is used with a 24VAC thermostatEstimated Reading Time: 13 mins. They Honeywell Aquastat Relay (LE) provides total convenience and control for a range of installations. This is an immersion-type controller that combines high limit protection with switching relay control of the burner and circulator motors. The Honeywell LE Aquastat Immersion Controller Relay is available with horizontal and /5(94). LE/U. Aquastat Relay, – F range with 15 degree F fixed differential, low volt/millivolt. This product is not for sale on this site. It may or may not be available on www.doorway.ru Product Info.
I have a Burnham Revolution gas boiler with a Honeywell LE aquastat. When the boiler calls for heat the boiler appears to run, but the burners do not ignite until i give the aquastat a couple of r In the burnham manual it lists 2 one is a honeywell LD and the other one the manual li. LA,B,C,E,G,L,M AQUASTATfi RELAYS 3 Š10 Table 1. Aquastat Relay models. a Multizone control can be provided by using a separate circulator and R Relay for each zone. b Contacts are not powered; they are rated for switching of millivoltage loads. Replacement Aquastat Assemblies: See Table 2 and Fig. 3 through 7. Honeywell Aquastat Relay Le Wiring Diagram- wiring diagram is a simplified okay pictorial representation of an electrical www.doorway.ru shows the components of the circuit as simplified shapes, and the capacity and signal associates surrounded by the devices.
Honeywell LE is a vertical-mount aquastat with a 15deg DIFF control using a 24VAC transformer. Its high limit opens the burner circuit only. A remote low limit controller can be added. Honeywell LE is a vertical-mount aquastat with an 15deg DIFF control and a 50VAC transformer. The limit control can switch both burner and circulator. www.doorway.ru LE,J are used to power zone valves, low voltage (24 Vac) load must not exceed A; a A load is the maximum permissible when ambient temperature exceeds 77°F (25°C). Use additional transformer(s) when load exceeds these ratings. www.doorway.ru LE is used to power SV/ SV, use separate transformer to power zone valves. CONTROLLER CASE. Capillary Length (mm) Electrical Ratings, Burner. Electrical Ratings, Circulator. Technical Documents. Product Data and Specifications-Product Data for LA, LE, LJ Aquastat Relays (English) Installation Materials-Installation Instructions for LA, LE, and LJ Aquastat Relays (French).