Shodex ri-101 operating manual
Browse our other Testing and Analyzing Equipment. X Login. Keep me signed in. Please refer photo's for more information about this product Differential Refractive Index Detectors are used for detecting little or no UV active samples such as sugars or polymers. The Shodex RI, employs a number of improvements for shortening the time for stabilization.
By using a micro-processor it is capable of automatic start-up from eluent replacement to checking the base-line stabilization. The detector is fitted with external input and output terminals as well as RSC communication ports, permitting advanced automation by linking the detector with various HPLC systems, enabling advanced automation by combining the detector with various chromatographs. Differential Refractive Index Detectors are used for detecting little or no UV active samples such as sugars or polymers.
Main features: superior base line stability intuitive operating using easily overview of operational conditions and baseline trend automatic start-up function for reference cell filling and baseline stabilization checking HELP function for easy validation and calibration control mode by keypad, or RS optimized temperature control method guarantee quick base line stabilization leak sensor stop the pump by solvent leakage various automated function Noise Level2.
Shipping Height: Shipping Quotes take Business Days to Process. This item has today. What is the fix for this? I have not found someone that says they can fix this. Is this something I can fix? Also does someone know a company that could fix this? Hi Normally for RI detectors you need to flush reference cell and sample cell with the same solvent to get diode balance 0. However there should be manual procedure at least there is for Agilent RI where the position of the light beam falling on the diode is adjusted using the zero glass adjustment screw it is not very complicated procedure So you've got 2 options: - send it to service or call service - or do it yourself always risky if you have no idea what you're doing Regards Tomasz Kubowicz.
Meanings of these fonts are: Instrument blue text marks the name of the window to which the text refers. Open File italics describes the commands and names of fields in Clarity, parameters that can be entered into them or a window or dialog name when you already are in the topic describing the window. The control module enables direct control of the instrument over serial line.
Fig 1: Shodex RI detector Direct control means that the detector can be completely controlled from the Clarity environment. Note: Modern computers usually have only one if any serial COM port installed. Invoke the System Configuration dialog accessible from the Clarity window using the System - Configuration Page 9 You may fill in the custom Device Name.
A new Shodex RI- detector section enabling the monitoring of the current detector state will be also created in Device Monitor window.
If more than one detector is available, it is possible to select between them by using the Select Detector combobox on the top of the dialog. Page 12 Setting this parameter to other value than Sampling Period means that the detector will filter the data and only send averaged values to Clarity. When the temperature reaches the desired value with the tolerance set here, the detector gets to the READY state.
Page Method Setup - Advanced 4. Fig 6: Method Setup - Advanced The list of available auxiliary signals is shown in the table in the lower part of the dialog.