Astm c1396 pdf
ASTM C1396 PDF >> READ ONLINE
13. Water Absorption (ASTM C630, ASTM C1396, ASTM C1658): Less than 5 percent of weight. 14. Mold Resistance (ASTM D3273): 10, in a test as manufactured. 15. Microbial Resistance (ASTM D6329): Will not support microbial growth. 16. Acceptable Products: a. 1/2 inch DensArmor Plus Interior Panel, Georgia-Pacific Gypsum. ASTM C1396/C1396M-14a Standard Specification for Gypsum Board 1.1 This specification covers the gypsum boards described in 1.1.1 - 1.1.9. 1.2 Specifications applicable to all gypsum boards are located in Section 1 - 4 and 13 - 15. Specifications applicable to specific gypsum boards are located in the following sections: A. Provide panels complying with ASTM C1177 and ASTM C1396, Type X, water-resistant core, 16 mm (5/8 inch) thick. 2.3 ACCESSORIES A. ASTM C1047, except form of 0.39 mm (0.015 inch) thick zinc coated steel sheet or rigid PVC plastic. 2.4 FASTENERS A. ASTM C1002 and ASTM C840, except as otherwise specified. or sealed using noncombustible materials. ASTM E136 is often the test standard referred to in terms of defining what materials meet this requirement. Historically, loose mineral wool fiber has been used for fireblocking. What is ASTM E136? Fireblocking predates actual through-penetration testing standards such as ASTM E814 or UL1479. Manufactured to meet ASTM C1396/C1396M, Section 5, Type X; CAN/CSA-A82.27-M, Type X; and NYC MEA # 204-08-M. Standards and Codes UL classified for surface burning (File No. R16102) (per ASTM E84 and CAN/ULC-S102) Flame spread = 0; Smoke developed = 0; Meeting IBC, Section 803.1, Class A Core combustibility (per ASTM E136) Non-combustible ASTM C1396/C1396M + RL, 2017 Edition, July 1, 2017 - STANDARD SPECIFICATION FOR GYPSUM BOARD - INCLUDES STANDARD + REDLINE (PDF) There is no abstract currently available for this document ASTM C1396/C1396M-00. 1.1 This specification covers the gypsum boards described in 1.1.1-1.1.9. Note 1—Specifications C840, C841, C844 and C1280 contain application procedures for gypsum board. 1.1.1 Gypsum wallboard , designed for use on walls, ceilings, or partitions and that affords a surface suitable to receive decoration. 1.1 This specification covers the gypsum boards described in 1.1.1 - 1.1.9. Note 1: Specifications C840, C841, C844 and C1280 contain application procedures for gypsum board. 1.1.1 Gypsum wallboard, designed for use on walls, ceilings, or partitions and that affords a surface suitable to receive decoration. ASTM C1396/C1396M-06a Standard Specification for Gypsum Board. standard by ASTM International, 11/01/2006. This document has been replaced. View the most recent version. View all product details Options Availability; Priced From ( in USD ) PDF ASTM Federal Standard SS--30d Application Standards Product 12 12.7mm 8 1.9mm Type X Widths 48" (1219mm) 48" (1219mm) Water Absorption (ASTM C 473) % by weight <5% <5% Edges Tapered Tapered Smoke Developed 5 5 Mold Resistance Rating** (ASTM D 3273) * Special lengths or edges may be available as a special order. Please contact your CertainTeed
894, 204, 850, 627, 346.